O₂ · N₂ · INERT · CRYOGENIC SERVICE

Valves & Regulators for O₂, N₂ & Cryogenic Gases

Oxygen, nitrogen, inert-gas and cryogenic systems need valves, regulators and instruments that are cleaned, rated and tested for the gas they carry. JSES supplies the full range for industrial-gas applications, from oxygen-cleaned valves and regulators to pressure, differential-pressure, flow and temperature instruments; we sell the equipment, not the gases.

✓ Cleaned for O₂ service

✓ Cleaning and test certificates

✓ Quote in 48 hours

Oxygen and nitrogen pressure regulating station with copper-alloy valves and stainless pipework
EIGA GUIDELINES

Oxygen service expertise

In-house knowledge of EIGA guidelines for oxygen service, including cleaning of equipment for oxygen service and oxygen pipeline and piping systems. We supply components cleaned for oxygen service and provide the relevant oxygen-cleaning and service-suitability certificates on request.

Product groups

Schubert & Salzer sliding gate control valve
01
O₂ service

Oxygen-cleaned valves

Ball, globe, shut-off and control valves degreased and cleaned for oxygen, in materials suited to oxygen service.

  • Cleaned and sealed, with cleaning certificate
  • Manual, pneumatic or electric actuation
  • Selected for gas velocity and pressure drop
Pressure regulator with gauges and relief valve for oxygen and nitrogen service
02
O₂ · N₂ · inert gas

Regulators & gas control

Pressure regulators, purge panels and manifolds for oxygen, nitrogen, argon and other inert gases.

  • Single- and two-stage regulators
  • Purge and blanketing set-ups
  • Relief valves and gauges included
Extended-bonnet cryogenic globe valves and safety relief valve
03
Down to −196 °C

Cryogenic valves

Extended-bonnet valves for liquid nitrogen, oxygen and argon in storage, vaporiser and transfer lines.

  • Extended bonnet for cold service
  • Shut-off, check and safety relief valves
  • Cryogenic test on request
Pressure and DP transmitters: Siemens SITRANS P320/P420, Endress+Hauser Cerabar PMP71B and Yokogawa EJA110E
04
Pressure · DP

Pressure & differential-pressure instruments

Pressure and DP transmitters, gauges and switches for O₂, N₂, inert and cryogenic lines, including DP level measurement on cryogenic tanks.

  • Versions cleaned for oxygen service
  • Oxygen-compatible fill fluids and seals
  • Remote seals and manifolds on request
Flow measurement: Endress+Hauser Proline t-mass F 300 and Emerson Rosemount 3051 DP flow
05
Flow

Flow measurement

Flow meters and DP-based flow measurement for oxygen, nitrogen and inert gases, from burner skids to plant distribution.

  • Sized to your gas, pressure and flow range
  • Oxygen-service cleaning available
  • Totalising and 4–20 mA / HART outputs
Temperature instruments: Endress+Hauser iTHERM TM131, Siemens SITRANS TS500 and Yokogawa YTA610
06
Temperature

Temperature instruments

RTD and thermocouple sensors with transmitters and thermowells, including low-temperature versions for cryogenic lines.

  • Pt100 for cryogenic service
  • Thermowells to your process connection
  • Head-mounted or field transmitters
Oxygen-service cleaning certificate, pressure test report and material certificate
07
Documentation

Cleaning & test certificates

Valves and instruments ship with the documents your plant or approval body needs.

  • Oxygen-service cleaning certificate
  • Pressure test and calibration certificates
  • Material certificate (EN 10204 3.1) on request

Brands we source

Schubert & Salzer · Emerson · Endress+Hauser · Siemens · Yokogawa

WHAT TO SEND US

Tell us the gas and the conditions

Valves and instruments for industrial gases are selected for the gas, the cleanliness level and the temperature. Send us:

Frequently asked questions

Oxygen makes many materials burn more easily, so anything in contact with oxygen must be free of oil, grease and particles, made from oxygen-compatible materials and, for instruments, filled with an oxygen-compatible fluid. Valves must also keep gas velocity within safe limits. Items are cleaned, sealed and supplied with a cleaning certificate.

Yes. In-house knowledge of EIGA guidelines for oxygen service, including cleaning of equipment for oxygen service and oxygen pipeline and piping systems. We supply components cleaned for oxygen service and provide the relevant oxygen-cleaning and service-suitability certificates on request.

Pressure and differential-pressure transmitters, gauges and switches, flow meters, and temperature sensors and transmitters, for oxygen, nitrogen, argon and other inert gases, and low-temperature versions for cryogenic service.

Yes. Cryogenic tank level is usually measured by differential pressure; we supply DP transmitters and the related valves and manifolds for it.

An oxygen-service cleaning certificate where needed, pressure test and calibration certificates, and, on request, material certificates to EN 10204 3.1.

No. JSES supplies the valves, regulators and instruments for industrial-gas systems. Please contact your gas supplier for the gas itself.

Meet Aastha

No time to write? Tell Aastha your requirement and she’ll pass it to our engineers.

Send your requirement

    Gas trains, valves and instruments for industrial gas applications, backed by in-house engineering for combustion, cryogenic, food & beverage and chemical process systems to EN and US standards.

    Contact Information

    © 2026 Jupiter Software & Engineering Solutions LLP. All rights reserved. · GSTIN 27AAWFJ3059L1ZL · LLPIN ACT-0794